Customization: | Available |
---|---|
Nature of Operation: | Transmitting Antenna |
VSWR: | 2 |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
General Specifications | ||
High-Pressure Alarm | Factory set (Above the upper limit 3kPa) | |
Low-Pressure Alarm | Factory set (Below the lower limit 1kPa ) | |
Excess Run Alarm | Factory set (>30min) | |
Dew point Alarm | >-5ºC | |
Timer function | Query the running times within 24 hours (delete after 24 hours) | |
Counting function | Query the startup times within 24 hours (delete after 24 hours) | |
Leakage Detection | Air-tightness detection | |
Dehydrator Type | Automatic Membrane | |
Output Pressure | 1-99 kPa adjustable | |
Output Flow Rate | 6.7 L/min (±10% at 25ºC) | |
Output dew point | Better than-45ºC | |
Acoustic Noise | ≤60dB at 1m | |
Port Count | 4/8 | |
Port Size | 6-R1/8 | |
Tube Type | 4×6mm (ID×OD) | |
MTBF | 25000h | |
Mounting | Table | Wall | EIA 19 in | ETSI | |
Environmental Specifications | ||
Operating temperature | '-40ºC to 65ºC | |
Operating Humidity | ≤ 95% | |
Electrical Specifications | ||
Power Consumption, Maximum | 270W | |
Power Consumption, Minimum | 2W | |
Circuit Breaker Size | 1.5A | |
Voltage | 220Vac±10% or 110Vac±10%or -48Vdc±10% | |
Models Information | ||
Models | Ports | Communication type |
KD-H | DB9 | Without communication function |
KD-H-M | RS485, Modbus RTU | |
KD-H-NC | RJ45 | TCP Server/TCP Client/UDP/MULTICAST |
KD-H-S | SNMP | |
Packaging and Weights | ||
Product Dimension | 260(D)×218(H)×482(L)mm | |
Packed Dimension | 380(D) ×380(H)×560(L) mm | |
Net Weight | 13.5kg | |
Gross Weight | 17.5kg |